The T35-11, BT35, and FT35 series axial flow fans serve as replacements for the 30K4 series. The T35...
+ VIEW MORECentrifugal Ventilator
The Model 11-62A Low-Noise Multi-Blade Centrifugal Ventilator is designed and manufactured to meet the growing demands of the purification industry and environmental noise reduction initiatives. Its design incorporates a multi-objective optimization methodology—balancing various aerodynamic parameters such as noise levels and efficiency—to achieve optimal performance matching for the entire unit. Characterized by excellent aerodynamic performance, the fan features an impeller that has undergone rigorous dynamic balancing; consequently, it offers smooth operation, low noise levels, minimal vibration, and a long service life. It is widely utilized in public venues—such as corporate cafeterias, hotels, restaurants, and eateries—for kitchen exhaust, range hood extraction, and general ventilation purposes. Furthermore, it is well-suited for integration into production machinery across various sectors, including grain processing, chemical manufacturing, and plastics processing.
| Immediately | Import and export size | Import and export size | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| D1 | D2 | D3 | A1 | A2 | A3 | A4 | axb | cxd | ||||||||||||||||||||||||||||||||||||||||||||||||||
| 3 | φ258 | φ290 | φ310 | 215 | 285 | 220 | 290 | 250 | 255 | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3.5 | φ300 | φ344 | φ363 | 227 | 297 | 253 | 325 | 262 | 290 | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4 | φ350 | φ395 | φ420 | 320 | 395 | 315 | 390 | 360 | 355 | |||||||||||||||||||||||||||||||||||||||||||||||||
| 4.5 | φ390 | φ435 | φ465 | 320 | 390 | 365 | 435 | 355 | 400 | |||||||||||||||||||||||||||||||||||||||||||||||||
| 5 | φ460 | φ495 | Φ520 | 340 | 475 | 315 | 390 | 440 | 355 | |||||||||||||||||||||||||||||||||||||||||||||||||
| 6 | φ530 | φ565 | φ595 | 315 | 400 | 470 | 552 | 360 | 512 | |||||||||||||||||||||||||||||||||||||||||||||||||
| Immediately | Shape and installation dimensions | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| M | G | L | H | K | a | b | d3 | n1-d1 | n2-d2 | |||||||||||||||||||||||||||||||||||||||||||||||||
| 3 | 580 | 560 | 620 | 385 | 210 | 400 | 240 | φ12 | φ8 | φ10 | ||||||||||||||||||||||||||||||||||||||||||||||||
| 3.5 | 675 | 560 | 600 | 445 | 245 | 400 | 270 | φ14 | φ8 | φ10 | ||||||||||||||||||||||||||||||||||||||||||||||||
| 4 | 775 | 800 | 760 | 500 | 280 | 440 | 375 | φ14 | φ10 | φ12 | ||||||||||||||||||||||||||||||||||||||||||||||||
| 4.5 | 880 | 910 | 765 | 560 | 310 | 505 | 385 | φ14 | φ10 | φ12 | ||||||||||||||||||||||||||||||||||||||||||||||||
| 5 | 970 | 1000 | 750 | 635 | 330 | 635 | 395 | φ14 | Φ10 | φ12 | ||||||||||||||||||||||||||||||||||||||||||||||||
| 6 | 1165 | 1205 | 860 | 765 | 400 | 740 | 465 | φ14 | φ10 | Φ12 | ||||||||||||||||||||||||||||||||||||||||||||||||
| Immedlately | Power (kw-P) |
Voltage (V) |
Speed (r/min) |
Tratfic (m³ /h) |
Total pressure (Pa) |
| 2.5A | 0.75 | 220 | 1400 | 1370-2760 | 480-345 |
| 2.5A | 0.75 | 380 | 1400 | 1370-2760 | 480-345 |
| 3A | 0.75 | 380 | 910 | 1408-2850 | 300-260 |
| 3A | 1.5 | 220 | 1420 | 2150-4270 | 654-535 |
| 3A | 1.5 | 380 | 1420 | 2150-4270 | 654-535 |
| 3A | 2.2 | 220 | 1420 | 2200-4400 | 650-520 |
| 3A | 2.2 | 380 | 1420 | 2200-4400 | 650-520 |
| 3.5A | 1.1 | 380 | 910 | 3200-5080 | 438-367 |
| 3.5A | 3 | 220 | 1420 | 5075-8065 | 1000-840 |
| 3.5A | 3 | 380 | 1420 | 5075-8065 | 1000-840 |
| 3.5A | 2.2 | 220 | 1420 | 2365-5613 | 702-767 |
| 3.5A | 2.2 | 380 | 1420 | 2365-5613 | 702-767 |
| 4A | 2.2 | 380 | 960 | 4860-7807 | 684-586 |
| 4A | 3 | 380 | 960 | 5742-8830 | 670-520 |
| 4.5A | 3 | 380 | 960 | 6175-9220 | 896-837 |
| 4.5A | 4 | 380 | 960 | 7342-11120 | 880-837 |
| 5A | 4 | 380 | 960 | 8127-10051 | 1167-1090 |
| 5A | 5.5 | 380 | 960 | 8857-13021 | 1147-1018 |
| 6A | 7.5 | 380 | 960 | 9820-16894 | 1200-990 |
| 6.5A | 11 | 380 | 970 | 10800-21000 | 1270-1100 |
| 7A | 11 | 380 | 730 | 12053-21330 | 1080-950 |
The T35-11, BT35, and FT35 series axial flow fans serve as replacements for the 30K4 series. The T35...
+ VIEW MORE
The T35-11, BT35, and FT35 series permanent magnet variable-frequency axial-flow fans serve as repla...
+ VIEW MORE
The Model 4-72C centrifugal ventilator is designed to convey air and other gases that are non-flamma...
+ VIEW MORE
The Models 9-19 and 9-26 high-pressure centrifugal ventilators are widely utilized for conveying mat...
+ VIEW MORE
The Model 11-62A Low-Noise Multi-Blade Centrifugal Ventilator is designed and manufactured to meet t...
+ VIEW MORE
The Model 4-72 series plastic centrifugal ventilators manufactured by our factory are meticulously c...
+ VIEW MORE
The FA-B series consists of single-phase, capacitor-run, axial-flow exhaust fans, while the FTA seri...
+ VIEW MORE
The YBX3 series of high-efficiency, flameproof, three-phase asynchronous motors is a fully enclosed,...
+ VIEW MORE
Copyright ©
Zhejiang Shenli Explosion proof Electromechanical Co., Ltd.